Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
2.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599692

RESUMO

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Seguimentos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Qualidade de Vida , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco/efeitos adversos
3.
Int J Cardiol ; : 131934, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.

4.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905381

RESUMO

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Volume Sistólico , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Função Ventricular Esquerda , Sistema de Registros
5.
Clin Res Cardiol ; 112(7): 967-980, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37129668

RESUMO

BACKGROUND: Anaemia and iron deficiency (ID) are independently associated with adverse outcomes in patients with cardiovascular diseases, especially in those with heart failure. Here, we aimed to clarify the long-term effect of anaemia and ID on outcomes in patients undergoing transcatheter mitral edge-to-edge repair (TEER) for relevant mitral regurgitation (MR) as well as to relate these to the underlying MR aetiology. METHODS: 833 patients (median age 77.1 years, 40.7% women, 63.3% secondary MR) treated by TEER between 09/2008 and 07/2019 were included and stratified according to baseline anaemia (hemoglobin < 12 g/dL in women and < 13 g/dL in men) or ID. RESULTS: Anaemia and ID were frequent with 61.6% and 68.1%, respectively. Anaemic patients had a lower functional status at baseline and were less likely to improve after TEER. In addition, anaemia was associated with all-cause mortality (hazard ratio [HR] = 1.68, 95% confidence interval [CI] 1.36-2.07, p < 0.001) and the composite endpoint of death or heart failure (HF) rehospitalization (HR = 1.30, 95% CI 1.10-1.54, p = 0.002). In contrast, ID was not associated with either all-cause mortality or the composite endpoint of death or HF rehospitalization. CONCLUSION: Patients undergoing TEER have high rates of both anaemia and ID. However, anaemia is associated with worse functional baseline status and post-interventional improvements compared to ID. Furthermore, anaemia is linked to higher rates of mortality and HF rehospitalization, particularly in those with secondary MR.


Assuntos
Anemia , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Deficiências de Ferro , Insuficiência da Valva Mitral , Masculino , Humanos , Feminino , Idoso , Insuficiência da Valva Mitral/cirurgia , Anemia/complicações , Anemia/diagnóstico , Anemia/epidemiologia , Insuficiência Cardíaca/complicações , Readmissão do Paciente , Resultado do Tratamento
6.
J Am Coll Cardiol ; 82(4): 281-291, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37207923

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is known to be associated with substantial morbidity and mortality. OBJECTIVES: The authors sought to study the acute outcomes of subjects treated by tricuspid transcatheter edge-to-edge repair with the TriClip system (Abbott) in a contemporary, real-world setting. METHODS: The bRIGHT (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device) postapproval study is a prospective, single-arm, open-label, multicenter, postmarket registry conducted at 26 sites in Europe. Echocardiographic assessment was performed at a core laboratory. RESULTS: Enrolled subjects were elderly (79 ± 7 years of age) with significant comorbidities. Eighty-eight percent had baseline massive or torrential TR, and 80% of subjects were in NYHA functional class III or IV. Successful device implantation occurred in 99% of subjects, and TR was reduced to ≤moderate at 30 days in 77%. Associated significant improvements in NYHA functional class (I/II, 20% to 79%; P < 0.0001) and Kansas City Cardiomyopathy Questionnaire score (19 ± 23 points improvement; P < 0.0001) were observed at 30 days. With baseline TR grade removed as a variable, smaller right atrial volume and smaller tethering distance at baseline were independent predictors of TR reduction to ≤moderate at discharge (OR: 0.679; 95% CI: 0.537-0.858; P = 0.0012; OR: 0.722; 95% CI: 0.564-0.924; P = 0.0097). Fourteen subjects (2.5%) experienced a major adverse event at 30 days. CONCLUSIONS: Transcatheter tricuspid valve repair was found to be safe and effective in treating significant TR in a diverse, real-world population. (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device [bRIGHT]; NCT04483089).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Idoso , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Índice de Gravidade de Doença
7.
Artigo em Inglês | MEDLINE | ID: mdl-36948892

RESUMO

BACKGROUND: Data regarding the impact of the tricuspid valve gradient (TVG) after tricuspid transcatheter edge-to-edge repair (TEER) are scarce. OBJECTIVES: This study sought to evaluate the association between the mean TVG and clinical outcomes among patients who underwent tricuspid TEER for significant tricuspid regurgitation. METHODS: Patients with significant tricuspid regurgitation who underwent tricuspid TEER within the TriValve (International Multisite Transcatheter Tricuspid Valve Therapies) registry were divided into quartiles based on the mean TVG at discharge. The primary endpoint was the composite of all-cause mortality and heart failure hospitalization. Outcomes were assessed up to the 1-year follow-up. RESULTS: A total of 308 patients were included from 24 centers. Patients were divided into quartiles of the mean TVG as follows: quartile 1 (n = 77), 0.9 ± 0.3 mm Hg; quartile 2 (n = 115), 1.8 ± 0.3 mm Hg; quartile 3 (n = 65), 2.8 ± 0.3 mm Hg; and quartile 4 (n = 51), 4.7 ± 2.0 mm Hg. The baseline TVG and the number of implanted clips were associated with a higher post-TEER TVG. There was no significant difference across TVG quartiles in the 1-year composite endpoint (quartiles 1-4: 35%, 30%, 40%, and 34%, respectively; P = 0.60) or the proportion of patients in New York Heart Association class III to IV at the last follow-up (P = 0.63). The results were similar after adjustment for clinical and echocardiographic characteristics (composite endpoint quartile 4 vs quartile 1-quartile 3 adjusted HR: 1.05; 95% CI: 0.52-2.12; P = 0.88) or exploring post-TEER TVG as a continuous variable. CONCLUSIONS: In this retrospective analysis of the TriValve registry, an increased discharge TVG was not significantly associated with adverse outcomes after tricuspid TEER. These findings apply for the explored TVG range and up to the 1-year follow-up. Further investigations on higher gradients and longer follow-up are needed to better guide the intraprocedural decision-making process.

8.
Eur J Heart Fail ; 25(6): 872-884, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36994662

RESUMO

AIMS: The impact of the cardio-hepatic syndrome (CHS) on outcomes in patients undergoing mitral valve transcatheter edge-to-edge repair (M-TEER) for relevant mitral regurgitation (MR) is unknown. The objectives of this study were three-fold: (i) to characterize the pattern of hepatic impairment, (ii) to investigate the prognostic value of CHS, and (iii) to evaluate the changes in hepatic function after M-TEER. METHODS AND RESULTS: Hepatic impairment was quantified by laboratory parameters of liver function. In accordance with existing literature, two types of CHS were distinguished: ischaemic type I CHS (elevation of both transaminases) and cholestatic type II CHS (elevation of two out of three parameters of hepatic cholestasis). The impact of CHS on 2-year mortality was evaluated using a Cox model. The change in hepatic function after M-TEER was assessed by laboratory testing at follow-up. We analysed 1083 patients who underwent M-TEER for relevant primary or secondary MR at four European centres between 2008 and 2019. Ischaemic type I and cholestatic type II CHS were observed in 11.1% and 23.0% of patients, respectively. Predictors for 2-year all-cause mortality differed by MR aetiology. While in primary MR cholestatic type II CHS was independently associated with 2-year mortality, ischaemic CHS type I was an independent mortality predictor in secondary MR patients. At follow-up, patients with MR reduction ≤2+ (obtained in 90.7% of patients) presented with improved parameters of hepatic function (median reduction of 0.2 mg/dl, 0.2 U/L and 21 U/L for bilirubin, alanine aminotransferase and gamma-glutamyl transferase, respectively, p < 0.01). CONCLUSIONS: The CHS is frequently observed in patients undergoing M-TEER and significantly impairs 2-year survival. Successful M-TEER may have beneficial effects on CHS.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fígado , Resultado do Tratamento , Cateterismo Cardíaco
9.
Clin Res Cardiol ; 112(6): 824-833, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36739561

RESUMO

BACKGROUND: Patients undergoing left atrial appendage (LAA) occlusion (LAAO) are multi-morbid, including mitral valve disease (MVD) which is associated with anatomic changes of the left atrium (LA). This study aims to identify how atrial myopathy in MVD influences outcomes in LAAO. METHODS: Atrial myopathy in MVD was defined as LA diameter > 45 mm (♀) and > 48 mm (♂) and existing MVD or history of surgical/interventional treatment. Patients were compared with controls from the prospective, multicentre LAArge registry of LAAO. RESULTS: A total of 528 patients (52 MVD, 476 no-MVD) were included. The MVD group was significantly more likely to be older (78.2 years vs 75.9 years, p = 0.036) and female (59.6% vs 37.8%, p = 0.002). Altered LA anatomy was observed in MVD with significantly larger LA diameter (53 mm vs. 48 mm, p < 0.001) and LAA Ostia [at 135° 23.0 mm (20.5, 26.0) vs 20.0 mm (18.0, 23.0), p = 0.002]. Implant success was high with 96.2% and 97.9%, respectively, without differences in severe complications (7.7% vs 4.6%, p = 0.31). One-year mortality (17.8% vs 11.5%, p = 0.19) and a combined outcome of death, stroke, and systemic embolism (20.3% vs 12.4%, p = 0.13) were not different. Independent predictors of the combined outcome were peripheral artery disease (HR 2.41, 95% CI 1.46-3.98, p < 0.001) and chronic kidney disease (HR 3.46, 95% CI 2.02-5.93, p < 0.001) but not MVD and atrial myopathy. CONCLUSION: Patients with MVD present with altered LA anatomy with increased LA and LAA diameter. However, procedural success and safety in LAAO are not compromised. One-year mortality is numerically higher in patients with MVD but driven by comorbidities.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Doenças das Valvas Cardíacas , Doenças Musculares , Acidente Vascular Cerebral , Humanos , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Átrios do Coração/diagnóstico por imagem , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Acidente Vascular Cerebral/etiologia , Doenças Musculares/complicações , Resultado do Tratamento
10.
Int J Cardiol ; 371: 312-318, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36115443

RESUMO

BACKGROUND: Body surface area (BSA) has been reported to be the stronger predictor for prognosis than body mass index in heart failure (HF) patients. The sex-specific association of BSA with mortality has been unclear. METHODS: EuroSMR, a European multicenter registry, included patients who underwent edge-to-edge repair (TEER) for secondary mitral regurgitation (SMR). The outcome was two-year all-cause mortality. RESULTS: The present cohort included 1594 HF patients (age, 74 ± 10 years; male, 66%). Association of calculated BSA with two-year all-cause mortality was evaluated. Patients were classified into three BSA groups: the lowest 10% (S), the highest 10% (L), and intermediate between S and L (M). Mean BSA was 1.87 ± 0.21 m2 (male, 1.94 ± 0.18 m2; female, 1.73 ± 0.18 m2). The association of BSA with the endpoint in females showed a U-shaped curve, indicating worse prognosis for both S and L. The association in males followed a linear regression, demonstrating better prognosis for L. Hazard ratio (HR) of L to S in males was 0.43 (95% confidence interval [CI], 0.25-0.74; p = 0.002), whereas HR of L to M in females was 1.76 (95% CI, 1.11-2.78; p = 0.016) (p for interaction = 0.003). CONCLUSIONS: Sex-specific association patterns demonstrate the complex influence of anthropomorphic factors in HF patients scheduled for TEER. Further investigation beyond simple evaluation of weight and height is needed for better comprehension of the obesity paradox and better prediction of the results of transcatheter therapy in HF patients.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Cateterismo Cardíaco/métodos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia
11.
Catheter Cardiovasc Interv ; 100(7): 1291-1299, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36378678

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is independently associated with increased morbidity and mortality. Percutaneous transcatheter approaches may offer an alternative for patients not amenable to surgery. METHODS: TriCLASP is a prospective, single-arm, multicenter European post-market clinical follow-up study (NCT04614402) to evaluate the safety and performance of the PASCAL system (Edwards Lifesciences) in patients with severe or greater TR. At 30 days, a composite of major adverse events (MAEs) adjudicated by a clinical events committee, echocardiographic parameters adjudicated by core laboratory, and clinical, functional, and quality-of-life measures were evaluated. RESULTS: Mean age of the 74 enrolled patients was 80.3 years, with 58.1% female, 90.5% systemic hypertension, and 77.0% in New York Heart Association (NYHA) class III/IV. Mean Society for Thoracic Surgeons score (MV repair) was 9.0%. TR severity was significantly reduced at discharge (p < 0.001) and sustained at 30 days (p < 0.001), and 90.0% of patients achieved ≤moderate TR. The composite MAE rate at 30 days was 3.0%, including 4 events in 2 patients: cardiovascular mortality 1.5%, stroke 1.5%, renal complications requiring unplanned dialysis or renal replacement therapy 1.5%, and severe bleeding 1.5%. There were no nonelective tricuspid valve reinterventions, major access site and vascular complications, major cardiac structural complications, or device embolizations. NYHA class I/II was achieved in 55.8%, 6-minute walk distance improved by 38.2 m (p < 0.001), and Kansas City cardiomyopathy questionnaire scores improved by 13.4 points (p < 0.001). CONCLUSION: Experience with the PASCAL transcatheter valve repair system in a European post-market setting confirms favorable safety and effectiveness at 30 days. TR significantly reduced, and clinical, functional, and quality-of-life outcomes significantly improved. This study is ongoing. Clinical Trial Registration: The study is ongoing and registered on ClinicalTrials.gov as NCT04614402. The current analysis is an interim report.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso de 80 Anos ou mais , Masculino , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Resultado do Tratamento , Índice de Gravidade de Doença
12.
Eur J Heart Fail ; 24(11): 2162-2171, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36054557

RESUMO

AIMS: Right ventricular dysfunction (RVD), as expressed by right ventricular to pulmonary artery coupling, has recently been identified as a strong outcome predictor in patients undergoing mitral valve edge-to-edge repair (M-TEER) for secondary mitral regurgitation (MR). The aim of this study was to define RVD in patients undergoing M-TEER for primary MR (PMR) and to evaluate its impact on procedural MR reduction, symptomatic development and 2-year all-cause mortality. METHODS AND RESULTS: This multicentre study included patients undergoing M-TEER for symptomatic PMR at nine international centres. The study cohort was divided into a derivation (DC) and validation cohort (VC) for calculation and validation of the best discriminatory value for RVD. A total of 648 PMR patients were included in the study. DC and VC were comparable regarding procedural success and outcomes at follow-up. Sensitivity analysis identified RVD as an independent predictor for 2-year mortality in the DC (hazard ratio [HR] 2.37, 95% confidence interval [CI] 1.47-3.81, p < 0.001), which was confirmed in the VC (HR 2.06, 95% CI 1.36-3.13, p < 0.001). Procedural success (MR ≤2+) and symptomatic improvement at follow-up (New York Heart Association [NYHA] class ≤II) were lower in PMR patients with RVD (MR ≤2+: 82% vs. 93%, p = 0.002; NYHA class ≤II: 57.3% vs. 66.5%, p = 0.09 for with vs. without RVD). In all PMR patients, the presence of RVD significantly impaired 2-year survival after M-TEER (HR 2.23, 95% CI 1.63-3.05, p < 0.001). CONCLUSIONS: Mitral valve edge-to-edge repair is an effective treatment option for PMR patients. The presence of RVD is associated with less MR reduction, less symptomatic improvement and increased 2-year mortality. Accordingly, RVD might be included into pre-procedural prognostic considerations.


Assuntos
Insuficiência Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Humanos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia
13.
JACC Cardiovasc Imaging ; 15(11): 1843-1851, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35842361

RESUMO

BACKGROUND: Among patients with severe functional mitral regurgitation (FMR), atrial functional mitral regurgitation (aFMR) represents an underrecognized entity. Data regarding outcomes after mitral valve transcatheter edge-to-edge repair (M-TEER) in aFMR remain scarce. OBJECTIVES: The objective of this study was to analyze the outcome of aFMR patients undergoing M-TEER. METHODS: Using patients from the international EuroSMR (European Registry of Transcatheter Repair for Secondary Mitral Regurgitation) registry undergoing M-TEER for FMR, the authors analyzed baseline characteristics and 2-year outcomes in aFMR in comparison to non-aFMR and ventricular FMR. Additionally, the impact of right ventricular dysfunction (RVD) (defined as right ventricular to pulmonary artery uncoupling) on outcome after M-TEER was assessed. RESULTS: Among 1,608 FMR patients treated by M-TEER, 126 (7.8%) were categorized as aFMR. All 126 aFMR patients had preserved left ventricular function without regional wall motion abnormalities, left arterial dilatation and Carpentier leaflet motion type I. Procedural success (defined as mitral regurgitation ≤2+ at discharge) was 87.2% (P < 0.001) and New York Heart Association (NYHA) functional class significantly improved during follow-up (NYHA functional class III/IV: 86.5% at baseline to 36.6% at follow-up; P < 0.001). The estimated 2-year survival rate in aFMR patients was 70.4%. Two-year survival did not differ significantly between aFMR, non-aFMR, and ventricular FMR. Besides NYHA functional class IV, RVD was identified as a strong independent predictor for 2-year survival (HR: 2.82 [95% CI: 1.24-6.45]; P = 0.014). CONCLUSIONS: aFMR is a frequent cause of FMR and can be effectively treated with M-TEER to improve symptoms at follow-up. Advanced heart failure symptoms and RVD were identified as important risk factors for survival in aFMR patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Direita , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valor Preditivo dos Testes , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Função Ventricular Esquerda , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
14.
JACC Cardiovasc Interv ; 15(9): 922-934, 2022 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-35512916

RESUMO

OBJECTIVES: The aim of this study was to investigate the adverse impact of elevated postprocedural mitral valve pressure gradient (MPG) on outcome in a real-world population of patients with severe mitral regurgitation (MR) who underwent transcatheter mitral valve edge-to-edge repair (TEER). BACKGROUND: TEER has become a routine treatment alternative for patients with severe MR at high surgical risk. The consequences of elevated MPG after TEER have been subject to controversial debates. METHODS: All consecutive patients undergoing TEER for either severe degenerative MR (DMR) or functional MR (FMR) at a high-volume center between September 2008 and January 2020 were prospectively included and followed periodically. Postprocedural MPG by discharge transthoracic echocardiography was considered elevated at ≥5 mm Hg. The primary combined endpoint was death or heart failure rehospitalization after 5 years. RESULTS: A total of 713 patients undergoing TEER (DMR, n = 265; FMR, n = 445) were included. Elevated postprocedural MPG was present in 37.0% of those with DMR (n = 98) and 22.0% of those with FMR (n = 98). In contrast to patients with FMR, 6-minute walk distance did not improve in patients with DMR with elevated MPG. Kaplan-Meier analyses did not demonstrate significant differences for the primary endpoint in patients with DMR (low vs elevated MPG, 67.3% vs 74.4%; P = 0.06) and those with FMR (78.6% vs 74.8%; P = 0.54). After adjustment, elevated MPG was an independent predictor of the primary endpoint in patients with DMR (HR: 1.59; 95% CI: 1.03-2.45; P = 0.034) but not in those with FMR (HR: 0.87; 95% CI: 0.63-1.22; P = 0.43). CONCLUSIONS: Elevated postprocedural MPG is an independent predictor of adverse clinical and functional outcomes in patients with DMR but not in those with FMR.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Ecocardiografia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
16.
Circ Cardiovasc Interv ; 15(3): e011302, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35236096

RESUMO

BACKGROUND: Patients with severe tricuspid regurgitation present late and are often ineligible for surgery or transcatheter repair systems. Transfemoral venous implantation of a bicaval valved stent has been proposed as therapeutic option in selected patients. The aim of this study was to summarize the early procedural and clinical outcomes of the novel TRICENTO system for the treatment of patients with symptomatic severe tricuspid regurgitation. METHODS: All consecutive patients treated with the custom-made TRICENTO implant at the participating centers were included in this retrospective multicentre registry. RESULTS: A total of 21 high-risk patients (mean age 76±7 years; 67% female) with severe or higher grade tricuspid regurgitation were analyzed. The majority of the patients were in New York Heart Association class III/IV (95%), had peripheral edema (95%), and previous hospitalization for right heart failure (67%). Technical success was 100%, and there was no case of in-hospital mortality. During follow-up (median 61 days), symptomatic improvement was observed (65% in New York Heart Association class I/II; P<0.001). Computed tomography revealed asymptomatic fractures of the TRICENTO prosthesis in 3 patients. Cardiac magnetic resonance imaging obtained in 7 patients showed a significant decrease (252±65 mm3 at baseline versus 216±58 mm3 at follow-up, P=0.006) of right ventricular end-diastolic volume. The overall-survival rate was 76% at 1 year. CONCLUSIONS: The present data indicate the feasibility of transfemoral bicaval valved stent implantation for the treatment of severe tricuspid regurgitation. Functional improvement and signs of right ventricular reverse remodeling were observed. Stent fractures did not impair valve function, but require refinement of prosthesis design and careful assessment of eligibility criteria.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Stents , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
17.
J Am Coll Cardiol ; 79(5): 448-461, 2022 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-35115101

RESUMO

BACKGROUND: The right ventricular (RV)-pulmonary arterial (PA) coupling ratio relates the efficiency with which RV stroke work is transferred into the PA. Lower ratios indicate an inadequate RV contractile response to increased afterload. OBJECTIVES: This study sought to evaluate the prognostic significance of RV-PA coupling in patients with tricuspid regurgitation (TR) who were undergoing transcatheter tricuspid valve repair or replacement (TTVR). METHODS: The study investigators calculated RV-PA coupling ratios for patients enrolled in the global TriValve registry by dividing the tricuspid annular plane systolic excursion (TAPSE) by the PA systolic pressure (PASP) from transthoracic echocardiograms performed before the procedure and 30 days after the procedure. The primary endpoint was all-cause mortality at 1-year follow-up. RESULTS: Among 444 patients analyzed, their mean age was 76.9 ± 9.1 years, and 53.8% of the patients were female. The median TAPSE/PASP ratio was 0.406 mm/mm Hg (interquartile range: 0.308-0.567 mm/mm Hg). Sixty-three patients died within 1 year of TTVR, 21 with a TAPSE/PASP ratio >0.406 and 42 with a TAPSE/PASP ratio ≤0.406. In multivariable Cox regression analysis, a TAPSE/PASP ratio >0.406 vs ≤0.406 was associated with a decreased risk of all-cause mortality (HR: 0.57; 95% CI: 0.35-0.93; P = 0.023). In 234 (52.7%) patients with echocardiograms 30 days after TTVR, a decline in RV-PA coupling was independently associated with reduced odds of all-cause mortality (odds ratio [OR]: 0.42; 95% CI: 0.19-0.93; P = 0.032). The magnitude of TR reduction after TTVR (≥1+ vs <1+; OR: 2.53; 95% CI: 1.06-6.03; P = 0.037) was independently associated with a reduction in post-TTVR RV-PA coupling. CONCLUSIONS: RV-PA coupling is a powerful, independent predictor of all-cause mortality in patients with TR undergoing TTVR. These data suggest that the TAPSE/PASP ratio can inform patient selection and prognostication following TTVR.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Artéria Pulmonar/fisiopatologia , Pressão Propulsora Pulmonar/fisiologia , Volume Sistólico/fisiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Função Ventricular Direita/fisiologia , Idoso , Ecocardiografia Doppler , Feminino , Seguimentos , Humanos , Masculino , Período Pós-Operatório , Sistema de Registros , Estudos Retrospectivos , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Função Ventricular Esquerda
18.
EuroIntervention ; 18(3): 213-223, 2022 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-34992049

RESUMO

BACKGROUND: Transcatheter mitral valve implantation (TMVI) represents a novel treatment alternative for patients with severe mitral regurgitation (MR) considered ineligible for standard therapies. Data on the management of patients after TMVI screening are scarce. AIMS: We aimed to investigate outcomes of patients with severe MR undergoing TMVI evaluation treated with either TMVI, bailout-transcatheter edge-to-edge repair (bailout-TEER) or medical therapy (MT). METHODS: Between May 2016 and February 2021, 121 patients with MR considered ineligible for standard therapy were screened for TMVI. Outcomes were assessed for the subgroups of patients treated with TMVI, bailout-TEER and MT. The primary composite endpoint was all-cause death or heart failure hospitalisation after one year. RESULTS: The subgroups of TMVI (N=38), bailout-TEER (N=28) and MT (N=44) differed significantly with regard to MR aetiology (secondary MR: TMVI 68.4%, bailout-TEER 39.3%, MT 38.6%, p=0.014) and left ventricular ejection fraction (TMVI 37.0% [31.4-51.2], bailout-TEER 48.0% [35.3-58.3], MT 54.5% [40.8-60.0], p<0.001). At discharge and after one year, MR was reduced to ≤mild residual MR in all patients undergoing TMVI, while ≥moderate residual MR was present in 25.9% and 20.0% of patients, respectively, after bailout-TEER, and in 100.0% of patients on MT at one year. The primary endpoint occurred in 72.2% of patients remaining on MT, in 51.6% of patients undergoing TMVI and in 40.2% of those receiving bailout-TEER. CONCLUSIONS: In MR patients considered ineligible for standard therapy, TMVI provided acceptable clinical outcomes and MR elimination in the majority of patients. In screen-failed patients, bailout-TEER represented a reasonable alternative while MT was associated with poor outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
19.
Int J Cardiol Heart Vasc ; 38: 100946, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35028410

RESUMO

INTRODUCTION: Patients undergoing left atrial appendage closure (LAAC) are often severly anemic and close to the transfusion threshold. The aim was to investigate the prevalence of severe anemia in this cohort and if procedural safety is compromised compared with non-anemic patients. METHODS AND RESULTS: Comparison of severly anemic patients (Hb < 80 g/l) vs. non-severly anemic patients in the prospective, multicentre observational LAARGE registry of patients undergoing LAAC. A total of 638 patients (anemia 22.3% vs non-anemic 77.7%) were included. Anemic patients were older (77.1 years ± 7.9 vs 75.6 years ± 7.9, p = 0.014), had more comorbidities, higher CHA2DS2-VASc (4.8 vs 4.4, p = 0.017) and higher HAS-BLED (4.3 vs 3.8, p < 0.001) scores. Implant success was not influenced by anemia (99.3% vs 97.2%). Severe in-hospital (0.7% vs 5.6%, p = 0.01) and overall complications (8.5% vs 13.7%, p = 0.11) were less common in patients with anemia, driven by fewer pericardial effusions. Mortality was higher in anemic patients and associated with an increased hazard ratio, albeit not significantly (16.0% vs 10.3%, HR 1.61 (95%-CI: 0.97-2.67), p = 0.06). In the one-year follow-up, composite outcome of death, stroke or systemic embolism occurred in 22/142 anemic and in 54/496 non-anemic patients with an adjusted HR of 1.04 (95%-CI 0.62-1.73, p = 0.89). CONCLUSION: Severe anemia close to the transfusion threshold is common in patients undergoing LAAC. However, this does not influence in-hospital complications or implant success. One-year mortality is higher in anemic patients, mainly driven by co-morbidities.

20.
J Am Coll Cardiol ; 78(24): 2408-2421, 2021 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-34886961

RESUMO

BACKGROUND: Although mitral valve transcatheter edge-to-edge repair (M-TEER) achieves symptomatic benefit for a broad spectrum of patients with relevant secondary mitral regurgitation, conflicting data exist on its prognostic impact. OBJECTIVES: Adapted enrollment criteria approaching those used in the COAPT (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) and MITRA-FR (Percutaneous Repair or Medical Treatment for Secondary Mitral Regurgitation) trials were retrospectively applied to a European real-world registry to evaluate the influence of the respective criteria on outcomes. METHODS: A total of 1,022 patients included in the EuroSMR (European Registry of Transcatheter Repair for Secondary Mitral Regurgitation) registry and treated with M-TEER (November 2008 to September 2019) were stratified into COAPT-eligible (n = 353 [34.5%]) and COAPT-ineligible (n = 669 [65.5%]) as well as MITRA-FR-eligible (n = 408 [48.3%]) and MITRA-FR-ineligible (n = 437 [51.7%]) groups. RESULTS: Although the stratification of patients according to adapted MITRA-FR criteria led to comparable outcomes regarding all-cause mortality (P = 0.19), the application of adapted COAPT enrollment criteria demonstrated lower mortality rates in COAPT-eligible compared with COAPT-ineligible patients (P < 0.001). Multivariable Cox regression analysis identified New York Heart Association functional class IV (hazard ratio [HR]: 2.29; 95% confidence interval [CI]: 1.53-3.42; P < 0.001), logarithmic N-terminal pro-brain natriuretic peptide (HR: 1.47; 95% CI: 1.24-1.75; P < 0.001), and right ventricular-to-pulmonary arterial coupling (HR: 0.10; 95% CI: 0.02-0.57; P = 0.009) as independent predictors of outcome. Yet improvement of functional outcome was demonstrated in a subset of patients irrespective of COAPT eligibility status. CONCLUSIONS: In this real-world cohort of patients with secondary mitral regurgitation undergoing M-TEER, the retrospective application of adapted COAPT enrollment criteria successfully identified a specific phenotype demonstrating lower mortality rates. On the contrary, stratification according to adapted MITRA-FR criteria resulted in comparable outcomes.


Assuntos
Adaptação Fisiológica , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Sistema de Registros , Idoso , Europa (Continente)/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Prognóstico , Estudos Retrospectivos , Taxa de Sobrevida/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...